sunpeek.core_methods.dcam_lite_collective.dcam.convert_parameters.convert_to_2n#
- sunpeek.core_methods.dcam_lite_collective.dcam.convert_parameters.convert_to_2n(collector, f_prime_c, specific_volume, reference_conditions)#
This implements the parameter conversion of ISO 9806 to D-CAM 2-N parameters, under given reference conditions.
- Parameters:
collector (
CollectorType) – ISO 9806 performance parameters are taken from this collector.f_prime_c (
pint.Quantity,dimensionless) – Additionally to the ISO 9806 collector parameters, this function requires the collector efficiency factorf_prime_cof the collector.f_prime_cis the “constant collector efficiency factor”, usually denoted with an upper caseF'_c. Typical values forf_prime_care in the range of 0.95 to 0.98.f_prime_ccan be estimated from collector geometry and materials as F_c’ = u_int /(u_int + u_1) F’ = u_int /(u_int + u_1 + u_2 (T_s − T_amb ))specific_volume (
pint.Quantity,compatible with m**3 m**-2) – Specific fluid content of the collector, in terms of fluid volume per m² gross collector area.reference_conditions (
Dict[str,Q]) –Dictionary with reference conditions for parameter conversion. Expected keys and values: ref_irradiance : Q, compatible with W m**-2
Total irradiance in collector plane, used for collector parameter conversion.
- ref_deltaT_s_ambQ, compatible with K
Temperature difference between solid part of the collector (
T_sin the D-CAM 2-N model) and the ambient temperature.- ref_fluid_heat_capacityQ, compatible with ‘J kg**-1 K**-1’
Heat capacity of the heat transfer fluid, used for collector parameter conversion.
- ref_fluid_densityQ, compatible with ‘kg m**-3’
Density of the heat transfer fluid, used for collector parameter conversion.
- ref_specific_mass_flowQ, compatible with ‘kg m**-2 s**-1’
Mass flow per gross collector area of the array, used for collector parameter conversion.
- Returns:
Dataclass with values of the parameters for the MeQuSo / D-CAM 2-N model, as Quantity objects. Attributes: f_prime_c, kd, mc_f, mc_s, tau_alpha, u1, u2, u_int
- Return type:
Notes
For details about the D-CAM 2-N model, see MeQuSo final report https://doi.org/10.5281/zenodo.7615252 The math of the parameter conversion from ISO 9806 to 2-n (and back) is described in the paper draft Tschopp & Ohnewein (overleaf; not published yet 2025-10-22) or in Modelling and yield analysis for large solar thermal collector fields (Peter Zauner, 2025): https://repository.tugraz.at/publications/9ts5b-6sj93